S-3XL
Crafted from flame-resistant wood pulp fiber, this breathable outer layer helps block fine particles and light splashes. Its anti-static design makes it suitable for high-risk environmentslike energy, construction, and dust-prone work zones.

● Complies with CE certification for Type 5 and Type 6 protective garments,ensuring reliable protection against airborne partices and limited liquid splashes.
● Constructed from high-perfomance flame-retardant wood pulp fiber fabric,certified to EN 14116,Index 1.for reliable flame resistance.
● Successfully passed the EN 1149 anti-static test,ensuring safe use in electrostatic-sensitive environments.
● Offers excellent breathability while effectively shielding against solid particles and light liquid splashes.
● Designed to be worn as an outer layer over flame-retardant garments;not intended for direct skin contact.
| Physical Performance Test | |||
|---|---|---|---|
| ltem | Test Method | Test Result | Classification |
| Abrasion Resistance | ENISO 12947-2:2016 | >40rubs | Class2 |
| Puncture Resistance | EN 863:1995 | >10N | Class2 |
| Flex Cracking Resistance | ENISO7854:1997,Method | B >50000cycles | Class6 |
| Tensile Strength | EN ISO 139343-1:2013 | >30N | Class1 |
| Trapezoidal Tear Strength | ENISO9073-4:1997 | >20N | Class2 |
| Seam Strength | ENISO 13935-2:2014 | >50N | Class2 |
| Anti-Static | EN1149-1:2006 | / | pass |
| Chemical Resistance Test/EN ISO 6530-2005 | ||
|---|---|---|
| Chemicals | Repllency | Penetration |
| 30%H₂SO₄ | >90%/Class3 | <1%/Class3 |
| 10%NaOH | >90%/Class3 | <5%/Class2 |
| o-Xylene | >90%/Class2 | / |
| Butan-1-0l | >90%/Class2 | ≤5%/Class2 |
We are a professional manufacturer of protective clothing, so we can offer you factory direct prices.
Yes, we can accept OEM. We can design product and package based on your requirement.
It's no problem if you have small quantity, we would like to grow up with you together.
Please give me the exactly specification, So we can give you samples.